Latest Technology Product With Global Cummins Platform
» The Cummins® K38 series heavy-duty engine and world class Stamford alternator powered diesel generator set
» Proven technology with mechanical simplicity of Cummins PT fuel system.
» Exhaust after-treatment, 2P2L cooling system and in-cylinder solution to meet latest emission norms
» Smart aesthetic and superior finish
» Compact in size with optimum power to weight ratio
Environment friendly power
» Class defining technology engine is designed to meet stringent exhaust emission tests as per revised MoEF norms, thus offering environment friendly power.
» The Cummins® diesel generator sets are available with the lowest noise levels in its range
Lowest Operating Cost And Comprehensive Warranty
» Highly reliable and durable product
» All elements are designed to work together to maximize efficiency even at part loads, offering the advantage of lowest operating costs.
» 300 Hours/ 1 year service interval
» Industry acknowledged best-in-class comprehensive warranty on the entire package including rubber components
Single Source Power Assurance
» All the major components – the engine, alternator, control system and canopy are designed, manufactured and tested by Cummins India.
» Best and largest customer support network in India, capable of providing round-the-clock service and spares support
» All these things put together, Cummins® offers you SINGLE SOURCE POWER ASSURANCE
» Highly stable and reliable design with square engine
» Well designed air handling system with
» Dry type, Heavy duty, Replacable paper element air cleaner with restriction indicator
» Outboard aftercooling with 2 pump 2 loop system
» Optimised turbocharger for increased altitude capabilities
» Best in class fuel economy with
» PT fuel system with Electronic Step Timing Control (ESTC) injectors which smoothly stabilise engine speed under load with A1 class electronic governing
» Dual fuel filter system: Pre filter including water separator and Water In Fuel (WIF) sensor and main filter
» Standard integral set-mounted radiator system, designed and tested for 50°C ambient temperatures
» Full flow spin on lube oil filter
» Plate type lube oil cooler
» First fill of lube oil and coolant
» Electrical starter motor with soft start engagement feature
» Battery charging alternator
» 2 X 12 V DC battery
Alternator
» Stamford HC alternator frames from Cummins Generator Technologies
» 3 Phase reconnectable winding with 12 terminals brought out for connection
» Better motor starting capability
» Best in class efficiency
» Compact design with sealed bearings for longer life and lesser maintenance
» Impregnation on all wound components for better mechanical strength
Control Panel
Control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish.
The control panel consists of the following parts:
» PowerCommand 3.3 Controller
» Aluminum bus bars with suitable capacity with incoming/ outgoing terminals
» Indicating lamps for ‘Load ON’ and ‘Set Running’
» Instrument fuses duly wired and ferruled
» Air Circuit Breakers (ACB) of suitable rating with overload
and short circuit protections
PowerCommand 3.3 features
The PowerCommand® control system is a microprocessor based generator set monitoring, metering and control system with LCD display designed to meet the demands of today’s engine driven generator sets
» Intuitive operator interface which includes LED backlit LCD display with tactile feel soft-switches and generator set status LED lamps
» Integrated digital electronic voltage regulator with configurable torque matching.
» Digital electronic governing with temperature compensation
and smart starting.
» SAE J1939 interface to Full Authority Electronic (FAE) engines.
» AC Alternator Metering: L-L Voltage and L-N Voltage, Current (1 and 3 phase), kW, kVAR, Power factor, kVA (three phase and total), and Frequency.
» Utility/AC bus Metering: L-L Voltage and L-N Voltage, Current (1 and 3 phase), kW, kVAR, Power factor, kVA (three phase and total), and Frequency.
» Paralleling Control Functions: Digital frequency synchronization and voltage matching, Isochronous kW and kVAr load sharing controls, Droop kW and kVAr control, Sync check, Extended paralleling (Peak Shave/Base Load), Digital power transfer control (AMF), Load govern control, Load demand control
» Data Logging: Genset model data, Engine hours, Control hours, Engine starts, Load profile, kWh and upto 32 recent fault codes
» AC Alternator Protection: AmpSentry protective relays for short circuit shutdown, Over/Under voltage, Over/Under frequency, Over current, Overload, Reverse power, Reverse VAr, Phase rotation and Loss of AC sensing.
» Utility/AC bus protection: Over/Under voltage, Under frequency and Phase rotation
» Paralleling protections
» Control Functions: Start-stop with configurable time delay, Real time clock for fault and event time stamping, Exerciser clock and time of day start/ stop, Configurable glow plug control, Configurable cycle cranking, Load shed/ dump as per configurable priority
» 12 and 24 Volt DC operation
» Sleep mode
» Programmable I/Os (4 inputs and 2 outputs), expandable with AUX101/102 modules
» Self-Configuring PCCNet network
» Modbus interface (RS485 RTU)
» InPower compatible (PC based service tool)
» Certifications – meets the requirement of relevant UL, NFPA, ISO, IEC, Mil Std., CE and CSA standards
Silencer
Hospital grade silencer suitably optimized to meet stringent sound emission standards laid down by MoEF / CPCB
Mounting Arrangement
» Engine and alternator are mounted on a common MS fabricated base frame with AVM pads.